| Electrical
Controls - Components |
|
COMBINATION MOTOR STARTS |
|
Part No. |
Memo |
Photo |
|
PCP3367-1.0-1.6
PCP3367-1.6-2.5
PCP3367-2.5-4.0
PCP3367-4.0-6.3
PCP3367-6.3-10 |
Non-Reversing,
Combination Motor Starter, suitable
120, 208, 240, 380, 480 or 575 VAC,
single or three-phase, 50-60 Hz, at
currents in the range of 1.0-10
amps. NEMA 3,4,12 enclosure houses
disconnect and motor contactor
offering both short circuit and
electronic motor overload
protection. Does not include
120/1/60 control circuit.
*Select one of (5) amperage ranges
based on motor full-load current.
|
 |
|
PCP3378-1.0-1.6
PCP3378-1.6-2.5
PCP3378-2.5-4.0
PCP3378-4.0-6.3
PCP3378-6.3-10 |
Reversing, Combination Motor
Starter, suitable 208, 240, 380, 480
or 575 VAC, three-phase, 50-60 Hz,
at currents in the range of 1.0-10
amps. NEMA 3,4,12 enclosure houses
disconnect and motor contactor
offering both short circuit and
electronic motor overload
protection. Does not include
120/1/60 control circuit.
* Select one of (5) amperage ranges
based on motor full-load current. |
 |
|
PCP3368-0.0-1.5
PCP3368-1.5-2.3
PCP3368-2.3-4.5
PCP3368-4.5-6.0
Mounted & Wired |
Variable Speed Motor Controller,
suitable for 120/1/60 VAC input
power, 240/3/60 VAC output, in the
range of 0-6.0 amps. NEMA 1
enclosure.
* Select one of the (4) amperage
ranges based on motor full-load
current |
 |
PCP3371-0.0-1.5
PCP3371-1.5-2.3
PCP3371-2.3-4.5
PCP3371-4.5-8.0
Mounted & Wired |
Variable Speed Motor Controller,
suitable for 120/1/60 VAC input
power, 240/3/60 VAC output, in the
range of 0-8.0 amps. NEMA 1
enclosure.
* Select one of the (4) amperage
ranges based on motor full-load
current
|
 |
PCP3372-0.0-1.5
PCP3372-1.5-2.3
PCP3372-2.3-4.5
PCP3372-4.5-8.0
Mounted & Wired |
|
Variable Speed Motor
Controller, suitable for
208-240/3/60 VAC input
power, 240/3/60 VAC output,
in the range of 0-8.0 amps.
NEMA 1 enclosure.
* Select one of (4)
amperage ranges based on
motor full-load current.
|
|
 |
PCP3373-0.0-1.4
PCP3373-1.4-2.3
PCP3373-2.3-4.0
Mounted & Wired |
Variable Speed Motor Controller,
suitable for 380-480/3/60 VAC input
power, 480/3/60 VAC output, in the
range of 0-4.0 amps. NEMA 1
enclosure.
Select one of (3) amperage ranges
based on motor full-load current.
|
 |
|
MANUAL MOTOR STARTERS |
|
Part No. |
Memo |
Photo |
|
PCP3376-1.0-1.6
PCP3376-1.6-2.5
PCP3376-2.5-4.0
PCP3376-4.0-6.3
PCP3376-6.3-10
Mounted & Wired |
Manual Motor Starter or Motor
Disconnect, suitable for 120, 208,
240, 380, 480, or 575 VAC, single or
three phase, 50-60 Hz. in the range
of 1-10 full load amps. Provides
both short circuit and motor
overload protection. NEMA 4X
enclosure.
Select one of (5) amp ranges based
on motor full-load current. |
|
|
EMERGENCY STOPS |
|
Part No. |
Memo |
Photo |
|
PCP3361-10
PCP3361-30 |
Emergency
Stop Cable Switch Kit, 24 VDC, 120
VAC. Includes cable, tensioner,
eyebolts & springs.
* Select either 10 meters (32’-10”)
or 30 meters (98’-5”) kit based on
conveyor length. |
 |
|
PCP1946 |
Emergency Stop Pushbutton Station,
red mushroom head, 24 VDC, 120 VAC,
NEMA 4X enclosure. |
 |
|
PILOT DEVICES |
|
Part No. |
Memo |
Photo |
|
PCP1685 |
Pilot Light, red, indicates motor
ON/OFF, 24 VDC, 120 VAC. For use in
motor starters PCP3367 or PCP3378.. |
 |
|
PCP3360 |
Forward /Reverse/ Stop Pushbutton
Station, 24 VDC, 120 VAC,
non-illuminated, (1) normally open &
(1) normally closed contact, NEMA 4X
enclosure. |
 |
|
PCP3359 |
Start /Stop Pushbutton Station, 24 VDC, 120 VAC, non-illuminated, (1)
normally open & (1) normally closed
contact, NEMA 4X enclosure.. |
 |
|
PCP3365 |
Photo-Eye, Diffuse, 24-120 volt,
AC/DC, with 2M cable and mounting
bracket. |
 |
|
PCP3366 |
Photo-Eye, Polarized Retroflective,
24-120 volt AC/DC, with 2M cable,
reflector and mounting bracket.
|
 |
|
PCP3391 |
Proximity Switch, 20-250 volt AC/DC,
with 2M cable, normally open, 8 mm.
sensing range, 2.18” lg. stainless
barrel. |
 |
|
PCP3364 |
Limit Switch, Roller Arm,
24 VDC, 120 VAC, compact, center
rotary arm, side mount, with 3M
cable. |
 |
|
PCP3363 |
Limit Switch, Top Push,
24 VDC, 120 VAC, booted, side mount,
standard. |
 |
|
PCP3362 |
Limit Switch, Wobble Stick,
24 VDC, 120 VAC, compact, side
mount, with 3M cable. |
 |
|
PCP2074 |
Foot Switch,
120 VAC, single pole, double throw,
with guard. |
 |
|
PCP3374 |
Reversing Switch,
suitable for 120, 208, 240, 480 or
575 volt, 3-phase, 25-Amp maximum,
NEMA 4 enclosure. Assembly
required. |
 |
|
PCP3358-63 |
Control Transformer Kit,
for use with PCP3367 & PCP3378 motor
starters, 240 or 480 volt only.
Kit, includes 63 VA transformer,
240-480/1/60 primary, 120/1/60
secondary, (1) secondary and (2)
primary fuse clips (Fuses not
included); Auxiliary contacts for
disconnect, (2) N.O., Components
ship loose. |
 |
|
PCP0867 |
Power Cord,
with 120 volt molded plug, 25 ft.